Add to Cart
2B15-375,2B14-362, 2B14-450 Goodyear Ref. to Contitech FD530-30 CI 1/4 NPT Firestone W01-358-6800
OEM Number:
Goodyear:2B14-362,2B14 362,2B14362,
Goodyear:2B14-450,2B14 450,2B14450,
Goodyear:2B15-375,2B15 375,2B15375
WATSON & CHALIN AS-0034
Contitech:FD530-30 518 1/4 NPT
Contitech:FD530-30518 1/4 NPT
Firestone:W01-358-6800
Firestone:W01 358 6800
Firestone:W013586800
Firestone:21D-2
Firestone:21-2
Firestone:21 2
Contitech:FD 530-30 CI 1/4 NPT
❶Nut / Blind Nut
Top Cover Plate Screw (Nut) Tooth : 4 pcs X 3/8-16UNC
Screw Center Distance of Top Cover Plate : 159 mm
Bottom Cover Plate Screw (Nut) Tooth : 4 pcs X 3/8-16UNC
Screw Center Distance of Bottom Cover Plate : 159 mm
❷ Gas Hole / Air inlet / Air Fitting
Gas Hole / Air inlet : 1/4NPT
Center Distance Between Nut and Air inlet: 79.5 mm
❸ Cover Plate
Top Cover Plate Diameter (Width): 287 mm
Bottom Cover Plate Diameter (Width): 287 mm
❹Rubber Bellows
Rubber Bellows MAX Diameter : 401 mm
Compressed Height: 76.2mm / 3 inches
Maximum Height: 351 mm
Working Stroke : 254mm
❺ Bumper block / Buffer block
Without Bumper Block
❻ Girdle Hoop / Girdle Ring
With Girdle Hoop :One Pieces of Girdle Hoop
Compressed Height: 3.00 inches
Top Plate Number:3131 or 3134
Top Plate Width:11.31 inches
Piston Number:3130
Piston Width:11.31 inches
Firestone Bellows Number:21-2
Triangle Part Number:4518
Triangle Bellows Number:6336
Watson & Chalin #:AS-0034
Note:see W01-358-6808
Maximum diameter @ 100 PSIG (inches) | Bead type |
16 | 2 |
Maximum height (inches) | Blind nut center (inch) |
11.7 | 6.25 |
Maximum travel (inches) | Air isolator |
8.7 | Design height |
Minimum available height (inches) | 10.5 |
3 | Load (at design height): 40 psig (pounds) |
80PSI force (lb) at 1 inch stroke | 3460 |
11330 | Load (at design height): 60 psig (pounds) |
80PSI force (lb) at 3 inches stroke | 5350 |
10670 | Load (at design height): 80 psig (pounds) |
Maximum thrust at maximum stroke @ 80PSI (lbs) | 7280 |
5850 | Natural frequency (@ 80 psig) (cpm) |
material | 95 |
2 layer standard line | Isolation percentage at a forced frequency of 400 CPM |
Finishing details | 94.1 |
Isolation percentage at a forced frequency of 800 CPM | |
98.6 |